V1000 is a general purpose inverter drive covering the demands of a wide field of applications including Open-Loop-Vector functionality and the usage of PM motor without feedback
Product | V1000 |
---|---|
Max. Motor Output (kW) | 1~230 VAC, 0.1 – 4.0a |
3~200 VAC, 0.1 – 18.5 | |
3~400 VAC, 0.2 – 18.5 | |
Applicable Motor | Induction Motor (IM) |
Synchronous Motor (PM) | |
Control | V/f Control |
Open Loop Vector (OLV) | |
Open Loop Vector (OLV) for PM | |
Speed control range | V/f and V/F with PG 1:40 |
OLV 1:100 | |
CLV and OLV for PM 1:10*3 | |
Max. Output Freqency | 400 Hz |
Fieldbus Interfaces | RS-232C |
RS-422/485 (Memobus/Modbus) | |
MECHATROLINK-I | |
MECHATROLINK-II | |
Ethernet/IP | |
EtherCAT | |
Modbus TCP | |
PROFINET | |
CC-Link | |
DeviceNet | |
PROFIBUS-DP | |
CANopen | |
Standards | CE |
UL/cUL | |
RoHS | |
UL508C | |
EN ISO 13849-1 PLd | |
IEC/EN61508 SIL2 | |
Enclosure | IP20, NEMA1, IP66, Finless Type |
Functions | Speed/Torque Control Switching |
Energy Saving Function | |
Double Rating (ND/HD) | |
Speed Search | |
Slip Compensation | |
Torque Compensation | |
PID Control (with sleep function) | |
DriveWorksEZ (PLC SW) | |
Momentary Power Loss Ride-Thru | |
Application Parameter Presets | |
Preventive Maintenance Functions | |
RS-232C Interface |
V1000 Model Number | Pn(kw) | In(A) | Phd(kw) | Ihd(A) |
---|---|---|---|---|
CIMR-VTBA0001BAA | 0.2 | 1.2 | 0.1 | 0.8 |
CIMR-VTBA0002BAA | 0.4 | 1.9 | 0.2 | 1.6 |
CIMR-VTBA0003BAA | 0.75 | 3.3 | 0.4 | 3.0 |
CIMR-VTBA0006BAA | 1.1 | 6.0 | 0.75 | 5.0 |
CIMR-VTBA0010BAA | 2.2 | 9.6 | 1.5 | 8.0 |
CIMR-VTBA0012BAA | 3 | 12 | 2.2 | 11 |
V1000 Model Number | Pn(kw) | In(A) | Phd(kw) | Ihd(A) |
---|---|---|---|---|
CIMR-VT2A0001BAA | 0.2 | 1.2 | 0.1 | 0.8 |
CIMR-VT2A0002BAA | 0.4 | 1.9 | 0.2 | 1.6 |
CIMR-VT2A0004BAA | 0.75 | 3.5 | 0.4 | 3 |
CIMR-VT2A0006BAA | 1.1 | 6 | 0.75 | 5 |
CIMR-VT2A0010BAA | 2.2 | 8 | 1.5 | 8 |
CIMR-VT2A0012BAA | 3 | 9.6 | 2.2 | 11 |
CIMR-VT2A0020BAA | 5.5 | 12 | 3.7 | 17.5 |
CIMR-VT2A0030FAA | 7.5 | 17.5 | 5.5 | 25 |
CIMR-VT2A0040FAA | 11 | 19.6 | 7.5 | 33 |
CIMR-VT2A0056FAA | 15 | 68 | 11 | 47 |
CIMR-VT2A0069FAA | 18.5 | 80 | 15 | 60 |
V1000 Model Number | Pn(kw) | In(A) | Phd(kw) | Ihd(A) |
---|---|---|---|---|
CIMR-VT4A0001BAA | 0.4 | 1.2 | 0.2 | 1.2 |
CIMR-VT4A0002BAA | 0.75 | 2.1 | 0.4 | 2.1 |
CIMR-VT4A0004BAA | 1.5 | 4.1 | 0.75 | 3.4 |
CIMR-VT4A0005BAA | 2.2 | 5.4 | 1.5 | 4.8 |
CIMR-VT4A0007BAA | 3 | 6.9 | 2.2 | 5.5 |
CIMR-VT4A0009BAA | 3.7 | 8.8 | 3 | 7.2 |
CIMR-VT4A0011BAA | 5.5 | 11.1 | 3.7 | 9.2 |
CIMR-VT4A0018FAA | 7.5 | 17.5 | 5.5 | 14.8 |
CIMR-VT4A0023FAA | 11 | 23 | 7.5 | 18 |
CIMR-VT4A0031FAA | 15 | 31 | 11 | 24 |
CIMR-VT4A0038FAA | 18.5 | 38 | 15 | 31 |
V1000 Solar Technical Electrical specification | |
Pump inverter type | V/F control with derived MPPT Technology |
Dual supply ( Grid/ Solar) | Change over Available |
Input DC voltage (VOC) | 400volts DC for 200volts Class and 800volts class for 400 volts drive |
Input DC voltage ( Vmp) | 280 VDC tp 310 V Dc /510 V dc to 620 V DC |
Input DC current and power | As per motor capacity |
Min frequency | 0hz selectable setting range |
Max frequency | 120Hz |
Shock | 10 to less than 20 Hz (9.8m/s2) max |
Output Ac voltage | 3 phase 190-240v (-15%.+10%)/380-480V/(-15%,+10%) |
Output Ac voltage | As per chart above |
Motor frequency | 0-60Hz |
Motor control technology | V/f Control |
MPPT voltage | 230V to 360 V for 200 volts 460V to 620 V for 400 volts |
Over load capacity | 120% for ND |
Under voltage | 125V DC for 200 volts Class/ 250 for 400 volts Class |
Protection | Dry run , short circuit, Open Phase in input & output side, High Voltage, Low voltage and over load , earthing, recerse polarity. |
Ambient temp | -10deg to 50 deg |
Relative humidity | Max 95% relative humanity |