AC Drive - V1000

  • Overview & Application
  • Specification
  • MODELS & RATINGS
  • Solar Drive
  • Download
  • Inquiry

Overview

Compact Vector control Drive Ratings

  • 1 ~ 200V , 0.1kW to 4.0kw
  • 3 ~ 200V , 0.1kW to 18.5kW
  • 3 ~ 400V , 0.2kW to 18.5kW

V1000 is a general purpose inverter drive covering the demands of a wide field of applications including Open-Loop-Vector functionality and the usage of PM motor without feedback

Features

  • High flux braking for 50% reduction of braking time
  • Quick response on load and speed changes to improves machine performance.
  • Online Auto-Tuning to optimize for improved motor performance at low speed
  • Open Loop Vector Control for PM motor operation.
  • Safe Disable Inputs for Safe Torque OFF

Application

  • Compressor
  • Conveyor
  • Fan
  • HVAC
  • Pump

Specification

Product V1000
Max. Motor Output (kW) 1~230 VAC, 0.1 – 4.0a
3~200 VAC, 0.1 – 18.5
3~400 VAC, 0.2 – 18.5
Applicable Motor Induction Motor (IM)
Synchronous Motor (PM)
Control V/f Control
Open Loop Vector (OLV)
Open Loop Vector (OLV) for PM
Speed control range V/f and V/F with PG 1:40
OLV 1:100
CLV and OLV for PM 1:10*3
Max. Output Freqency 400 Hz
Fieldbus Interfaces RS-232C
RS-422/485 (Memobus/Modbus)
MECHATROLINK-I
MECHATROLINK-II
Ethernet/IP
EtherCAT
Modbus TCP
PROFINET
CC-Link
DeviceNet
PROFIBUS-DP
CANopen
Standards CE
UL/cUL
RoHS
UL508C
EN ISO 13849-1 PLd
IEC/EN61508 SIL2
Enclosure IP20, NEMA1, IP66, Finless Type
Functions Speed/Torque Control Switching
Energy Saving Function
Double Rating (ND/HD)
Speed Search
Slip Compensation
Torque Compensation
PID Control (with sleep function)
DriveWorksEZ (PLC SW)
Momentary Power Loss Ride-Thru
Application Parameter Presets
Preventive Maintenance Functions
RS-232C Interface

MODELS & RATINGS

Compact Vector Control Drive

200V Class Single Phase

V1000 Model Number Pn(kw) In(A) Phd(kw) Ihd(A)
CIMR-VTBA0001BAA 0.2 1.2 0.1 0.8
CIMR-VTBA0002BAA 0.4 1.9 0.2 1.6
CIMR-VTBA0003BAA 0.75 3.3 0.4 3.0
CIMR-VTBA0006BAA 1.1 6.0 0.75 5.0
CIMR-VTBA0010BAA 2.2 9.6 1.5 8.0
CIMR-VTBA0012BAA 3 12 2.2 11

200V Class Three Phase

V1000 Model Number Pn(kw) In(A) Phd(kw) Ihd(A)
CIMR-VT2A0001BAA 0.2 1.2 0.1 0.8
CIMR-VT2A0002BAA 0.4 1.9 0.2 1.6
CIMR-VT2A0004BAA 0.75 3.5 0.4 3
CIMR-VT2A0006BAA 1.1 6 0.75 5
CIMR-VT2A0010BAA 2.2 8 1.5 8
CIMR-VT2A0012BAA 3 9.6 2.2 11
CIMR-VT2A0020BAA 5.5 12 3.7 17.5
CIMR-VT2A0030FAA 7.5 17.5 5.5 25
CIMR-VT2A0040FAA 11 19.6 7.5 33
CIMR-VT2A0056FAA 15 68 11 47
CIMR-VT2A0069FAA 18.5 80 15 60

400V Class Single Phase

V1000 Model Number Pn(kw) In(A) Phd(kw) Ihd(A)
CIMR-VT4A0001BAA 0.4 1.2 0.2 1.2
CIMR-VT4A0002BAA 0.75 2.1 0.4 2.1
CIMR-VT4A0004BAA 1.5 4.1 0.75 3.4
CIMR-VT4A0005BAA 2.2 5.4 1.5 4.8
CIMR-VT4A0007BAA 3 6.9 2.2 5.5
CIMR-VT4A0009BAA 3.7 8.8 3 7.2
CIMR-VT4A0011BAA 5.5 11.1 3.7 9.2
CIMR-VT4A0018FAA 7.5 17.5 5.5 14.8
CIMR-VT4A0023FAA 11 23 7.5 18
CIMR-VT4A0031FAA 15 31 11 24
CIMR-VT4A0038FAA 18.5 38 15 31

Solar Drive


Compact Vector control Drive Ratings

  • 1 ~ 200V , 0.1kW to 4.0kw
  • 3 ~ 200V , 0.1kW to 18.5kW
  • 3 ~ 400V , 0.2kW to 18.5kW

V1000 solar drive is used solar pump Applications

  • Suitable for BLDC and PM motor
  • Suitable for surface mount and a submersible pump for 3 Phase 200Volts/400volts induction motor
  • wide range capacity from 0.1kw to 18.5kw
  • All day run stop restart mode management
  • Diagnostics and self-protection features.
  • Protection against dry run of pump
  • Simple and faster installation and commissioning.
  V1000 Solar Technical Electrical specification
Pump inverter type V/F control with derived MPPT Technology
Dual supply ( Grid/ Solar) Change over Available
Input DC voltage (VOC) 400volts DC for 200volts Class and 800volts class for 400 volts drive
Input DC voltage ( Vmp) 280 VDC tp 310 V Dc /510 V dc to 620 V DC
Input DC current and power As per motor capacity
Min frequency 0hz selectable setting range
Max frequency 120Hz
Shock 10 to less than 20 Hz (9.8m/s2) max
Output Ac voltage 3 phase 190-240v (-15%.+10%)/380-480V/(-15%,+10%)
Output Ac voltage As per chart above
Motor frequency 0-60Hz
Motor control technology V/f Control
MPPT voltage 230V to 360 V for 200 volts
460V to 620 V for 400 volts
Over load capacity 120% for ND
Under voltage 125V DC for 200 volts Class/ 250 for 400 volts Class
Protection Dry run , short circuit, Open Phase in input & output side, High Voltage, Low voltage and over load , earthing, recerse polarity.
Ambient temp -10deg to 50 deg
Relative humidity Max 95% relative humanity

Download

Inquiry

“Mifa Systems now represents Internationally reputed Process Control majors like:”

  • Toho Electronics, Japan
  • Keba AG, Austria
  • Yaskawa Electric
  • Rkc Instrument Inc., Japan
  • Mb Connectline GmbH, Germany
  • Wedgewood Analytical Inc., USA
  • Metrohm India
  • Gems Sensors & Controls, USA & UK.